48-7009-E 3-15
3-4 Examples of wiring
1) Input: K thermocouple, output 1: relay contact output and single phase 100 V
Temperature sensor
(K thermocouple)
External
relay
Heater
Connection configuration
Configuration example
TTM-204
Heater
External
relay
K thermocouple
* Take care when wiring, as thermocouple
has polarity of “+” and “-.
Power
supply
(Example) TTM-204
Power
supply
Terminal description for the above wiring example
Terminal No.
Description
Power supply
Output 1
Common
Normal open
Output 2
Not used in this case.
Output 3
Output 4
Not used in this case.
Input
Not used in this case.
-” side
“+” side
Communication
Not used in this case.
CT or DI input
Not used in this case.