48-7009-E 6-49
6.5 Output (from OUT 1 to OUT 7) type setting
■ Outputs 1 to 7 target connection setting
Timer 1 during-on-delay output
Timer 1 during-off-delay output
Timer 1 during-[on + off]-delay output
Timer 2 during-on-delay output
Timer 2 during-off-delay output
Timer 2 during-[on + off]-delay output
Timer 3 during-on-delay output
Timer 3 during-off-delay output
Timer 3 during-[on + off]-delay output
Transmission output (for analog output)
End Output (during program mode) 3
Set target connections for outputs 1 to 7.
This product allows free setting of output applications.
This product also allows duplicated setting of outputs 1 and 2 (such as setting the both outputs for either primary or secondary
output).
Note Transmission output can be selected only when the output 1 or 2 at order placement for the product is of analog output.
As no analog output being available for outputs 3 to 7, they cannot be set for the transmission output.
For operation of the event function 1 of the event output, see section of event function 1 operation on page 6-49.
For operations of the event functions 2 to 4 of the event output, see section of event functions 2 to 4 operations on pages 6-50
to 52.
For operation of the timer output, see section “5.4.5 Timer function” on pages 5-32 to 37.