Seite 1 - TOHO ELECTRONICS INC

TOHO ELECTRONICS INC. Operation Manual, Communications (TOHO protocol and MODBUS) Model: TTX-700 Designation: Module Controller

Seite 2 - Contents

3.4 Composition of a response message (transmitted from this product to a high-level computer) n For codes ① through ⑩, see "3.5. Descr

Seite 3

3.5 Description of codes n The codes from ① STX, ② address to ⑩ ERR as indicated below are expressed in ASCII codes. n For the ASCII cod

Seite 4

⑧ ACK It is an acknowledge code. If a message received by this product is error-free, this code will be incorporated in the "response me

Seite 5 - 2.1 Overview

3.6 Communications precautions 3.6.1 Communications timing Set a sufficient response delay to make sure that this product is switched over fro

Seite 6 - 2.4 Setting a parity

3.6.8 Storing data other than a store request message Store all parameters in the EEPROM in either of the two cases described below, even if no

Seite 7 - 2.7 Setting an address

4. Examples of TOHO communications 4.1 Examples of communications to be read Example: Request message: This requests this product set at addr

Seite 8 - 3.2 Message types

4.2 Examples of communications to be written Example: Request message: This requests this product set at address 03 to set "the E1F setti

Seite 9

5. Settings regarding MODBUS communications 5.1 Overview Before communications is performed, initial settings must be made on this product. En

Seite 10 - Negative

5.2 Setting a data length 5.3 Setting a stop bit length 5.4 Setting a parity While in the "Set a communications parameter" screen

Seite 11 - 3.5 Description of codes

5.6 Setting an address While in the "Set a communications address" screen on the preceding page, operate the ▲ and ▼ keys to make t

Seite 12

Contents 1. Before using the product...

Seite 13

6. MODBUS communications control 6.1 Communications procedure This product returns a "response message" in response to a "req

Seite 14

6.3 Composition of an RTU request message (transmitted from a high-level computer to this product) n For codes a) through i), see "6.5. D

Seite 15

6.3.3 Composition of a store request message a) Slave address 03H b) Function code 10H High level 02H c) Register address Low level 0EH Fi

Seite 16

Single a) Slave address 03H b) Function code 06H High level 00H c) Register address Low level C0H First register address High level 00H g) D

Seite 17 - 5.1 Overview

e) CRC-16 This error check code is for detecting message errors. This transmits a CRC-16 (tour redundancy code). The multinomial for genera

Seite 18 - 5.4 Setting a parity

6.6 Precautions on RTU communications 6.6.1 Communications timing Set a sufficient response delay to make sure that this product is switched

Seite 19 - 5.6 Setting an address

6.6.8 Changing the settings (SV or SV2) by communications during auto-tuning Even if the settings (SV or SV2) used in control for auto-tuning a

Seite 20 - 6.2 Message types

6.8 Composition of an ASCII request message (transmitted from a high-level computer to this product) n For the codes a) through g), see "

Seite 21

6.8.3 Composition of a store request message a) Start code “:” b) Slave address “0” , “3” c) Function code “1” , “0” High level “0” ,

Seite 22

6.9.2 Response message for a write/store request message a) Start code “:” b) Slave address “0” , “3” c) Function code “1” , “0” High l

Seite 23

6 MODBUS communications control... 20 6.1 Com

Seite 24

6.10 Description of ASCII codes n The codes from a) start code to b) slave address to j) error type described below are expressed in ASCII cod

Seite 25

i) Data portion This specifies data to be written in the register. The data is fixed at 4 bytes. This product will write data without the dec

Seite 26

6.11 Precautions on ASCII communications 6.11.1 Communications timing Set a sufficient response delay to make sure that this product is swit

Seite 27

6.11.8 Changing the settings (SV or SV2) by communications during auto-tuning Even if the settings (SV or SV2) used in control for auto-tuning

Seite 28

7. Specifications 7.1 Communications standard category: Compliant with EIA standard RS-485 7.2 Communications specifications 7.2.1 Commu

Seite 29

8. Connections 8.1 Connections for the RS-485 T/R(A)T/R(B)T/R(A)T/R(B)T/R(A)T/R(B)T/R(A)T/R(B) Communications is such that the connections

Seite 30

9. Table of ASCII codes ASCII code 00H 01H 02H 03H 04H 05H 06H 07H NUL SOH STX ETX EOT ENQ ACK BEL ASCII code

Seite 31

10. Table of identifiers (codes) MODBUS ADR Operation mode Low- level W High- level W Iden- tifier Character Name R/W Description 40000 40001

Seite 32

MODBUS ADR Event setting mode Low- level W High- level W Iden- tifier Character Name R/W Description 40072 40073 E1F Set an event output func

Seite 33

MODBUS ADR Screen-less commands Low- level W High- level W Iden- tifier Character Name R/W Description 40122 40123 TST Timer start stop R/W

Seite 34 - 7. Specifications

1. Before using the product 1.1 On this operation manual This is an operation manual regarding communications with a TTX-700 (hereinafter ref

Seite 35 - 8. Connections

TOHO ELECTRONICS INC. Head office: 1-13-21, Tanashioda, Sagamihara Kanagawa 229-1125 Japan. Phone: +81-42-

Seite 36 - 9. Table of ASCII codes

2. Settings regarding TOHO communications 2.1 Overview Before communications is performed, initial settings must be made on this product. En

Seite 37 - MODBUS ADR Operation mode

2.2 Setting a data length 2.3 Setting a stop bit length 2.4 Setting a parity 2.5 Setting whether to conduct a BCC check While in the &

Seite 38

2.7 Setting an address While in the "Set a communications address" screen on the preceding page, operate the ▲ and ▼ keys to make t

Seite 39

3. TOHO communications control 3.1 Communications procedure This product returns a "response message" in response to a "reque

Seite 40

3.3 Composition of a request message (transmitted from a high-level computer to this product) n For codes ① to ⑩, see "3.5. Description