Toho-electronics TTM-509 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 66
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
TOHO TOHO ELECTRONICS INC.
DWG. No.
45-4199-E
PAGE
12/66
When banks are switched over with DIs, the method of switchover varies according to the number of
DIs to be assigned.
When one DI is assigned
DI non-active, BANK0; DI active, BANK1
When two DIs are assigned
Status of DI2 Status of DI1 Banks selected
Non-active Non-active 0
Non-active Active 1
Active Non-active 2
Active Active 3
When three DIs are assigned
Status of DI3 Status of DI2 Status of DI1 Banks selected
Non-active Non-active Non-active 0
Non-active Non-active Active 1
Active Active Non-active 2
Non-active Active Active 3
Active Non-active Non-active 4
Active Non-active Active 5
Active Active Non-active 6
Active Active Active 7